lineHow to use Blood Pressure Monitor

Please follow the instructions below regarding the Blood Pressure Monitor.

accuniq-icon
accuniq-icon

Do not move or speak.
accuniq-icon
accuniq-icon

Press the start button.
accuniq-icon
accuniq-icon

Pull your arm out when you are done with the measurement.

lineCautions for Blood Pressure Monitor

Please follow the instructions below for the safe use of the machine.

accuniq-icon
Please do not wear thick clothes.
accuniq-icon
Do not use the machine while holding onto a beverage.
accuniq-icon
Please do not use the machine when you sweat a lot.
accuniq-icon
Please do not wipe the product with wet wipe.
accuniq-icon
Please avoid direct sunlight, high humidity or dusty place.

lineCautions for connecting the adapter

Please follow the instructions belowto ensure safety of the machine.

accuniq-img

Check the direction of the arrow on the connecting part of the adapter. You need to plug it as such that the arrow is facing up. Wrong connection can cause problems with the machine.

accuniq-img

When connecting the adapter, you need to properly connect it by pushing it sufficiently. Unstable connection can cause problems with the machine.

accuniq-img

Please use the adapter and power cable that Accuniq provided. We are not responsible for any problem that is due to the use of random accessory.

lineCautions for the customers

accuniq-img

Spillage of water on the product may cause fire.

Do not install the product when the voltage is unstable or where there is no ground.

Please get your Body Composition Analyzer and Blood Pressure Monitor checked every two years.

If you want to move the product you are using, contact us to request for our cooperation. Incorrect installation can cause problems with the product.

ACCUNIQ BP How to use

When you measure different arm. accuniq-img
Blood pressure is different from right arm and left arm. The difference is various and it is about 5~15mmHg. When you measure blood pressure for the first time, measure both arms and recognize higher blood pressure as your blood pressure. From now on, measure the arm which you had higher blood pressure. If difference between right arm and left arm is over 20~30mmHg, inform it to doctor.
Posture accuniq-img
Normally, measured blood pressure is higher when lying down than when seated, and higher when standing than when seated. When you measure blood pressure with supine position, you will obtain lower blood pressure of 10~15Hg in systolic, 10mmHg in diastolic, comparing to when seated or standing. Also, when you lie down in side ways, blood pressure of upper arm is lower than bottom arm
White Coat Hypertension accuniq-img
White coat hypertension is the case if you measure blood pressure at home by yourself, you can get normal blood pressure but, when you measure at hospital or with a doctor, blood pressure goes higher (In most cases, 20~30mmHg higher than normal).
Variation throughout the day and year. accuniq-img
A. Blood pressure changes variously throughout the day and it changes daily as well. The lowest blood pressure can be checked when person is asleep and highest blood pressure can be checked at 2~3 PM. Blood pressure falls down again and then rises slightly in the evening. Blood pressure is low in summer and high in winter. Moreover, diastolic rises about 15mmHg when measure in cool temperature room (15℃) comparing to warm temperature room (24℃).

If the user has arterial fibrillation accuniq-img
Arterial fibrillation is the most common arrhythmia for the aged and it is related to hypertension.
Measurement of blood pressure becomes difficult due to the irregular pulse, especially to analyze with korotkoff sound.
Result can be differed by catching diastolic on 4 or 5 point. accuniq-img
Each person has different swan 4 and 5 point. Sometimes 5 point is nearly 0 for some people.
In this case, difference occurs between catching 4 point to diastolic or 5 point to diastolic.
Auscultatory gap accuniq-img
Auscultatory gap is the period of irregular silent state and it occurs usually in the 2 phase.
If device misses the sound and catches the next sound as systolic, systolic will be measured extremely low.
If using inaccurate blood pressure monitor. accuniq-img
A. When you measure blood pressure, you should use accurate blood pressure monitor.
For aneroid sphygmomanometer, consistently check the zero point.
Accurate blood pressure can be derived with adjusting the zero point by regulation for other sphygmomanometer.
Others accuniq-img
A. Thickness of upper arm: Thicker arm gets higher measurement value.
Position of arm: When the arm is placed at a higher position than the heart, blood pressure will become lower than actual value, and if the arm is placed at a lower position than the heart, blood pressure will become higher.
During the fluid injection, measure the blood pressure with another arm.